Low Voltage Draw-out Switchgear

As a well-known supplier of power transmission and distribution equipment in China, Kexun’s GCK Low Voltage Draw-out Switchgear is a low-voltage distribution equipment widely used in industrial, commercial and civil buildings, which has the characteristics of compact structure, flexible operation, safety and reliability.

Category:

Industrial & Mining Enterprises

This is the most critical application scenario.

Metallurgical, chemical, petroleum, and cement plants: Numerous fans, pumps, and compressor motors in the workshop are centrally controlled (MCC motor control center). The entire production line cannot be shut down; individual motor failures require separate repair.

Low Voltage Draw-out Switchgear

Public Buildings & Transport Hubs

Airport terminals, subway stations, port terminals

Low Voltage Draw-out Switchgear

Manufacturing Industries

Textile, machinery processing, food processing, etc., where there are many motor circuits on site and high reliability maintenance is required.

Low Voltage Draw-out Switchgear

Product characteristics ◆

This GCK type LV Switchgear has the advantages of high breaking capacity, good dynamic and thermal stability, advanced and reasonable structure, practical electrical scheme, series, strong versatility, arbitrary combination of various scheme units, more circuits contained in one switchgear, floor space saving, beautiful appearance, high protection level, safety and reliability, convenient maintenance and so on. This product conforms to IEC439 NEMAICS2-322 standard, and also conforms to GB7251-87 “Low-voltage switchgear” national standard and ZBK36001-89 “Low-voltage withdrawable switchgear” professional standard

Main technical parameters

Number Item Data
1 Rated working frequency 50
2 Rated working voltage 380,660
3 Rated insulate voltage 660
4 Rated working current Horizontal bus 630-3150
vertical bus 600
5 Rated short-term withstand current Horizontal bus 80KA(virtual value)1s
vertical bus 50KA(virtual value)1s
6 Rated peak withstand current Horizontal bus 176KA/0.1s
vertical bus 110KA/0.1s
7 Main circuit connector(A) 200,400
8 Auxiliary circuit connector(A) 10
9 Working frequency withstand voltage(1min) 2500
10 IP degree IP40
11 Operating method Local, remote, automatic

Architectural feature

The basic switchgear frame of GCK type LV Switchgear is assembled structure. All the structural parts of the switchgear frame are connected with each other by screws to form a basic frame. Then, as required, doors, baffles, partitions, drawers, mounting brackets, bus bars and electrical components are added to assemble a complete switchgear. This LV switchgear has the following characteristics:

▶1. The frame is made of profiled steel, positioned by three-dimensional corner plate, and bolted without welding structure, thus avoiding welding deformation and stress and improving installation accuracy.

▶2. The mounting holes of frames and parts change according to the modulus E=20mm.

▶3. The internal structural parts are galvanized. After pickling and phosphating, the exterior is sprayed with electrostatic epoxy powder. 4. In the power center (PC) incoming switchgear, the top is the horizontal bus area, and the lower part of the horizontal bus area is the circuit breaker room. The circuit breakers can be equipped with domestic DW15C, ME and other series, and can also be equipped with various circuit breakers produced by foreign electric companies according to users’ needs, such as F series circuit breakers produced by ABB company and intelligent circuit breakers. In general, the PC unit has a main circuit (including bus coupler) with inverted rows. When the rated current is 630A-1600A, it occupies a switchgear with an overall size of 800×1000×2200 (width x depth x height). The main circuit without turnover occupies a switchgear with an external dimension of 800×800×2000 (width, depth and height). When the rated current is between 1600A-3150A, it occupies a switchgear with an overall size of 1000×1000×2200 (width x depth x height). There is no main switchgear that is turned over. When the rated current is 1600A-3150A, it occupies a switchgear with an external dimension of 1000×1000×220 (width× depth× height). The main circuit without turnover occupies a switchgear with an external dimension of 1000×800×2200 (width x depth x height).

▶4.The structure of the power center (PC) feeder switchgear is similar to that of the incoming switchgear. When the feeding current is 630A-1600A, a 1000×1000×2200 (width× depth× height) switchgear can be equipped with two loops, which are arranged up and down.

▶5. Motor Control Center (MCC) switchgear has two types: wall-mounted switchgear and non-wall-mounted switchgear, the top of which is a horizontal busbar area, and the drawer functional unit area is below the horizontal busbar area, the width of which is 600mm, and the height of the drawer functional unit area is 1840 mm. When the switchgear body is wall-mounted, the left part of the switchgear is a functional unit area, and the right part has a 200mm wide cable outlet area. The overall dimensions of the switchgear are 800/500/2200 (width/depth/height). When the switchgear is installed away from the wall, the width of the switchgear is 600mm, and the cable outlet area is at the back of the switchgear. The overall dimensions of the switchgear are 600×800(1000)×2200 (width x depth x height). There are two kinds of switchgear depths: 800 and 1000. We suggest that users choose a switchgear with a depth of 1000 to be consistent with the depth of the PC switchgear. When the drawer is drawn out of the switchgear, the live part in the switchgear is not exposed, which is safe and reliable.

Low Voltage Draw-out Switchgear

Overall & Installation Dimensions

Low Voltage Draw-out Switchgear

Swithgear width Swithgear depth Installation hole spacing a Installation hole spacing b
800 500 685 385
600 800 485 685
600 1000 485 885
800 800 685 685
800 1000 685 885
1000 800 885 685
1000 1000 885 885

GCK Installation Foundation

Low Voltage Draw-out Switchgear

Caution

▶When installing this product, the horizontal line between GCK type LV switchgears should be firmly and reliably connected.

▶The door of this product has an interlocking function with the main switch, that is, the door can only be opened under the condition of power failure. The other side of this product is a screw sealing plate, which has no interlocking function with the main switch. Therefore, please disconnect the power supply when disassembling the side plate of this product for maintenance.

▶Non-professionals should not open the switchgear for maintenance.

Cum sociis natoque penatibus

Purus in mollis nunc sed id semper risus. Velit laoreet id donec ultrices. Tellus pellentesque eu tincidunt tortor. Cum sociis natoque penatibus et. Vitae elementum curabitur vitae nunc sed velit. Nulla pellentesque dignissim enim sit amet venenatis urna cursus eget.

Mattis enim ut tellus elementum

Dolor morbi non arcu risus quis. Quisque non tellus orci ac auctor augue mauris augue. Ipsum a arcu cursus vitae congue mauris rhoncus aenean.

  • Cum sociis natoque penatibus et
  • Aliquam eleifend mi in nulla posuere
  • Ullamcorper malesuada proin libero
  • Purus in mollis nunc sed id

Reviews

There are no reviews yet.

Be the first to review “Low Voltage Draw-out Switchgear”

Your email address will not be published. Required fields are marked *