Environmental friendly gas insulate switchgear cabinet

The environmental friendly gas insulated switch gear cabinet produced by China factory Kexun Electric Co.,Ltd has the characteristics of simple structure, flexible operation, reliable interlocking and convenient installation, and is especially suitable for power distribution in urban residential areas, small secondary substations, switching stations, cable branch box, box-type substations, industrial and mining enterprises, shopping malls, airports, subways, wind power generation, hospitals, stadiums, railways, tunnels and other places.

Category:

Cable Branch Projects

Cable line is segmented and T-connected, replacing the traditional cable branch box, with switch protection and remote monitoring..

Environmental friendly gas insulate switchgear cabinet

Residential Power Distribution

High-rise and large-scale residential quarters distribute power, and the ring network is powered by dual power sources to ensure residents’ electricity consumption.

Environmental friendly gas insulate switchgear cabinet

Airports & Railways

Transportation hub, railway distribution station etc…

Environmental friendly gas insulate switchgear cabinet

Conditions of use

◆ Temperature :-25~45℃

◆ Max daily temperature: 35℃

◆ IP degree:Charged body seal IP67, switch cabinet shell IP4x

◆The surrounding air of Environmental friendly gas insulate switchgear cabinet should not be obviously polluted by corrosive combustible gas and water vapor.

◆There is no frequent violent vibration place, and the harshness design under harsh parts meets various requirements.

Standards

KXHB-12 type Environmental friendly gas insulate switchgear cabinet meets the standards below

◆Common technical requirements of GB/T 1022 standards for high-voltage switchgear and controlgear.

◆ GB/T39063640.5kV AC metal enclosed switchgear and control equipment.

◆ GB/T1985 High-voltage AC isolating switch and grounding switch

◆ GB/T38043.6-40.5kV AC high-voltage load switch

◆ GB/T1984 High-voltage AC circuit breaker

◆ GB/T4208 IP code of shell protection level

◆ GB/T7354 Partial Discharge Measurement

◆ GB/T311.1 Insulation coordination Part 1: Definition, principles and rules

Technical Parameters

◆ Circuit breaker Cabinet

Item Unit Data
Rated Voltage KV 12
Rated Frequency HZ 50
Rated insulate level 1Min working frequency withstand
Voltage
To groud,phase to phase KV 42
Break 48
Lighting impulse withstand voltage(peak) To groud,phase to phase KV 75
Break 85
1min power frequency withstand voltage of auxiliary/control circuit (to ground) KV 2
Rated Current A 630
Rated short-term withstand current(virtual value) Main circuit/Earthing switch kA 25/4s
Earthing circuit kA 21.7/4s
Rated peak withstand current Main circuit/Earthing switch kA 63
Earthing circuit kA 54.5
Rated short circuit break current and times kA/Time 25/30
Rated short circuit closing current (peak) kA 63
Rated cable charging break current A 25
Rated operating sequence of the breaker O-0.3s-CO-180s-CO
Mechanical life Breaker /Disconnector Time 10000/3000
IP degree Sealed box IP67
Switchgear shell IP4X
Gas voltage Rated gas charging level (20℃, gauge voltage) Mpa 0.02
Rated gas Min function level (20℃, gauge voltage) Mpa 0
Sealing performance, Annual leakage rate %/Year ≤0.05

◆Load switch cabinet

Item Unit Data
Rated Voltage KV 12
Rated Frequency HZ 50
Rated insulate level 1Min working frequency withstand
Voltage
KV
Lighting impulse withstand voltage(peak) KV
1min power frequency withstand voltage of auxiliary/control circuit (to ground) KV 2
Rated Current A 630
Rated short-term withstand current(virtual value) Main circuit/Earthing switch KA 25/4s
Earthing circuit KA 21.7/4s
Rated peak withstand current Main circuit/Earthing switch KA 63
Earthing circuit KA 54.5
Rated short circuit closing current (peak) Load switch/Earthing switch KA 63
Rated active load interrupting current A 630
Rated closed-loop interrupting current A 630
5% Rated active load interrupting current A 31.5
Rated cable charging break current A 10
Rated active load break times Time 100
Ground fault current breaking A/Time 31.5/10
The charging current of lines and cables is disconnected under the condition of ground fault. A/Time 17.4/10
Mechanical life Breaker /Disconnector A/Time 10000/3000
IP degree Sealed box IP67
Switchgear shell IP4X
Gas voltage Rated gas charging level (20℃, gauge voltage) Mpa 0.02
Rated gas Min function level (20℃, gauge voltage) Mpa 0
Sealing performance, Annual leakage rate %/Year ≤0.05

Typical scheme combination 1

Environmental friendly gas insulate switchgear cabinet

Typical scheme combination 2

Environmental friendly gas insulate switchgear cabinet

Note: The above typical combination reference scheme can be combined in various ways according to the needs of users.

ATS segmentation scheme

Environmental friendly gas insulate switchgear cabinet

Switch operating instructions

Switch position, state and interlock

Environmental friendly gas insulate switchgear cabinet

Operation steps:

Power transmission:Hang (close) the upper and lower doors with a circuit breaker (load switch) → the grounding switch with an isolating switch → the circuit breaker (load switch) with a power transmission is completed.

Power cut:Breaker (load switch) → disconnector → earthing switch → breaker (load switch) is unloaded (opened) and the door is blacked out.

Installation instructions

◆Foundation and overall dimensions

Environmental friendly gas insulate switchgear cabinet

◆Cabinet and overall installation dimensions

Environmental friendly gas insulate switchgear cabinet

Cum sociis natoque penatibus

Purus in mollis nunc sed id semper risus. Velit laoreet id donec ultrices. Tellus pellentesque eu tincidunt tortor. Cum sociis natoque penatibus et. Vitae elementum curabitur vitae nunc sed velit. Nulla pellentesque dignissim enim sit amet venenatis urna cursus eget.

Mattis enim ut tellus elementum

Dolor morbi non arcu risus quis. Quisque non tellus orci ac auctor augue mauris augue. Ipsum a arcu cursus vitae congue mauris rhoncus aenean.

  • Cum sociis natoque penatibus et
  • Aliquam eleifend mi in nulla posuere
  • Ullamcorper malesuada proin libero
  • Purus in mollis nunc sed id

Reviews

There are no reviews yet.

Be the first to review “Environmental friendly gas insulate switchgear cabinet”

Your email address will not be published. Required fields are marked *