Urban & Municipal Distribution
KXRM 6-24 Combined Type 24 kV GIS Switchgear produced by Kexun Electric realizes fault isolation for urban ring network power supply, outdoor box substation, underground power distribution room, urban transformation power distribution station, urban small opening and closing station and other scenes, and ensures uninterrupted power supply.

1.all-round 360 production line cutting group stop workflow, enabling automatic tube feeding, automatic feed, automatic cutting, automatic transmission operation.
2.Using KASRY Nesting programming system as a major programming tool, the software programming platform AUTOCAD basic, simple, graphical and intuitive, feature-rich, it can greatly improve operational efficiency.
Commercial Buildings
Shopping centers, office buildings, hospitals, data centers, hotels, large-scale complexes, medium-voltage distribution and transformer protection in buildings.

New Energy Projects
Photovoltaic power station, distributed photovoltaic power station and wind power station are equipped with energy storage, and new energy grid connection points and box transformers are equipped with medium-voltage ring network units.

Industrial Plants
Industrial parks, manufacturing factories, mines, food and beverage factories, sewage treatment plants, water plants, and factories have their own medium-voltage distribution stations.

Transportation Infrastructure
Airport, port, rail transit/subway, expressway service area, tunnel power distribution, and medium-voltage power distribution for transportation.

Standards
KXRM6-24 Combined Type 24KV GIS Switchgear meets the standards below
IEC60056、IEC60298、IEC60129、IEC60420、IEC60265、IEC60694 etc…
GB3804、GB3906、GB11022 etc…
Technical Parameters
| Item | Unit | C Module | F Module | V Module | CB Module | ||
|---|---|---|---|---|---|---|---|
| Load switch | Combined | Vacuum switch | Isolate Switch/Ground switch | VCB | Isolate Switch/Ground switch | ||
| Rated voltage | KV | 12/24 | 12/24 | 12/24 | 12/24 | 12/24 | 12/24 |
| Working frequency withstand voltage | KV | 42/50 | 42/50 | 42/50 | 42/50 | 42/50 | 42/50 |
| Lightning impulse withstand voltage | KV | 95/125 | 95/125 | 95/125 | 95/125 | 95/125 | 95/125 |
| Rated current | A | 630/630 | NOTE1 | 630/630 | 1250/630 | ||
| Breaking current | A | 630/630 | |||||
| Cable breaking current | A | 135/135 | |||||
| 5% Load breaking current | A | 31.5/- | |||||
| Grounding fault breaking current | A | 200/100 | |||||
| Grounding fault cable charging breaking current | A | 115/87 | |||||
| Short-circuit breaking current | KA | NOTE2 | 20/16 | 25/20 | |||
| Closing ability | KA | 63/52.5 | NOTE2 | 50/40 | 50/40 | 63/50 | 63/50 |
| Short-term withstand current (2s) | KA | 25/- | |||||
| Short-term withstand current (3s) | KA | -/21 | 20/16 | 20/16 | 25/20 | 25/20 | |
| Mechanical life | Time | 5000 | 3000 | 5000 | 2000 | 5000 | 5000 |
NOTE1:Depends on the rated current of fuse
NOTE2:Depends on the high voltage fuse
Module Configuration
▶D cabinet configuration See “Cable Connection Module without Grounding Knife” for standard configuration and characteristics.
▶Configuration of C cabinet See “Load Switch Module” for standard configuration and characteristics.
▶F cabinet configuration See “Vacuum Switch Module” for standard configuration and characteristics.
Additional Configurations
▶Capacitive voltage indicator of incoming bushing
▶Each air chamber is equipped with a pressure gauge for monitoring SF6 density.
▶Lifting lug
▶Operating handle
Structure & Dimensions