Indoor Transport Stations
Power distribution rooms in subway stations, toll stations and supporting indoor power distribution rooms in tunnels (* * Note: inflatable cabinets are preferred for wet and strongly corrosive tunnels, and HXGN is suitable for dry indoors )

Industrial & Mining Sites
Industrial parks, manufacturing workshops, water plants, sewage treatment plants, small and medium-sized mines, factory-owned power distribution rooms and workshop terminal power distribution.

Residential Power Distribution
The power distribution room, small opening and closing station and old distribution network in residential quarters were transformed, and the residential boxes were transformed into high-voltage units to ensure residents’ power supply.

Ring Main Unit Features
(1) Environmental protection advantages
◆Free SF gas: Environment friendly ring main unit adopts dry air, nitrogen or new environmental protection gas (such as G, Air Plus®, etc.) are used, which is in line with EU F-Gas regulations and China’s “double carbon” policy.
◆Low carbon emission: Compared with SF ring network cabinet, GWP (Global Warming Potential) approaches zero.
(2) Structural design
◆Modular design: The Environment friendly ring main unit unit of incoming line, outgoing line, metering and PT can be expanded.
◆Enclosed structure: The protection level of Environment friendly ring main unit reaches IP67, which is dustproof, moisture-proof and condensation-proof, suitable for harsh environment.
◆Compact size: it saves space than AIS ring network cabinet and is more environmentally friendly than traditional SF₆ GIS.
(3) Intelligent options
Intelligent monitoring (such as DTU, online temperature measurement, partial discharge monitoring, etc.) can be selected to support Internet of Things (IoT) access and realize remote operation and maintenance.
Technical Parameters of the Environment friendly ring main unit
◆ Circuit breaker Cabinet
| Item | Unit | Data | |||
|---|---|---|---|---|---|
| Rated Voltage | KV | 12 | |||
| Rated Frequency | HZ | 50 | |||
| Rated insulate level | 1Min working frequency withstand Voltage |
To groud,phase to phase | KV | 42 | |
| Break | 48 | ||||
| Lighting impulse withstand voltage(peak) | To groud,phase to phase | KV | 75 | ||
| Break | 85 | ||||
| 1min power frequency withstand voltage of auxiliary/control circuit (to ground) | KV | 2 | |||
| Rated Current | A | 630 | |||
| Rated short-term withstand current(virtual value) | Main circuit/Earthing switch | kA | 25/4s | ||
| Earthing circuit | kA | 21.7/4s | |||
| Rated peak withstand current | Main circuit/Earthing switch | kA | 63 | ||
| Earthing circuit | kA | 54.5 | |||
| Rated short circuit break current and times | kA/Time | 25/30 | |||
| Rated short circuit closing current (peak) | kA | 63 | |||
| Rated cable charging break current | A | 25 | |||
| Rated operating sequence of the breaker O-0.3s-CO-180s-CO | |||||
| Mechnical life | Breaker /Disconnector | Time | 10000/3000 | ||
| IP degree | Sealed box | IP67 | |||
| Swichgear shell | IP4X | ||||
| Gas pressure | Rated gas charging level (20℃, gauge pressure) | Mpa | 0.02 | ||
| Rated gas Min fuction level (20℃, gauge pressure) | Mpa | 0 | |||
| Sealing performance, | Annual leakage rate | %/Year | ≤0.05 | ||
◆Load switch cabinet
| Item | Unit | Data | |||
|---|---|---|---|---|---|
| Rated Voltage | KV | 12 | |||
| Rated Frequency | HZ | 50 | |||
| Rated insulate level | 1Min working frequency withstand Voltage |
KV | |||
| Lighting impulse withstand voltage(peak) | KV | ||||
| 1min power frequency withstand voltage of auxiliary/control circuit (to ground) | KV | 2 | |||
| Rated Current | A | 630 | |||
| Rated short-term withstand current(virtual value) | Main circuit/Earthing switch | KA | 25/4s | ||
| Earthing circuit | KA | 21.7/4s | |||
| Rated peak withstand current | Main circuit/Earthing switch | KA | 63 | ||
| Earthing circuit | KA | 54.5 | |||
| Rated short circuit closing current (peak) | Load switch/Earthing switch | KA | 63 | ||
| Rated active load interrupting current | A | 630 | |||
| Rated closed-loop interrupting current | A | 630 | |||
| 5% Rated active load interrupting current | A | 31.5 | |||
| Rated cable charging break current | A | 10 | |||
| Rated active load break times | Time | 100 | |||
| Ground fault current breaking | A/Time | 31.5/10 | |||
| The charging current of lines and cables is disconnected under the condition of ground fault. | A/Time | 17.4/10 | |||
| Mechnical life | Breaker /Disconnector | A/Time | 10000/3000 | ||
| IP degree | Sealed box | IP67 | |||
| Swichgear shell | IP4X | ||||
| Gas pressure | Rated gas charging level (20℃, gauge pressure) | Mpa | 0.02 | ||
| Rated gas Min fuction level (20℃, gauge pressure) | Mpa | 0 | |||
| Sealing performance, | Annual leakage rate | %/Year | ≤0.05 | ||
Applicable Standards
◆ Common technical requirements of GB/T 1022 standards for high-voltage switchgear and controlgear. ◆ GB/T39063640.5kV AC metal enclosed switchgear and control equipment.
◆ GB/T1985 High-voltage AC isolating switch and grounding switch
◆ GB/T38043.6-40.5kV AC high-voltage load switch
◆ GB/T1984 High-voltage AC circuit breaker
◆ GB/T4208 IP code of shell protection level
◆ GB/T7354 Partial Discharge Measurement
◆ GB/T311.1 Insulation coordination Part 1: Definition, principles and rules
Operating Conditions
◆ Maximum temperature: +45 degrees Celsius;
◆ Minimum temperature: -25 degrees Celsius;
◆ Maximum temperature: (24-hour average) +35 degrees Celsius;
◆ Maximum average relative humidity (24 hours 1: ≤ 95%; Altitude: ≤ 1500m; Seismic capacity: 8 degrees;
◆ Protection grade: charged body seal IP67, switch cabinet shell IP4x;
◆ The surrounding air should not be obviously polluted by corrosive combustible gas and water vapor.
◆ There is no frequent violent vibration place, and the harshness design under harsh parts meets all kinds of requirements.
◆ When it is used under normal environmental conditions beyond GB/T3906, the user shall negotiate with KEXR
Installation instructions